Quick diagnosis
What this code is telling you
Most likely trigger
pump hose installed incorrectly
Recommended replacement
Dehumidifier Drain Pump
Diagnostic path
4 ordered checks
Part fit
Exact model number required
Safety first
Before opening the appliance
Disconnect electrical power before removing panels or handling internal components. Do not bypass safety devices or perform live electrical testing unless you are qualified to do so.
Read the full safety disclaimerRoot cause
Why the control reported this error
E01 appears on certain 70-pint models with a built-in drain pump when Pump Out mode is selected but water is not being pumped out because pump hose installed incorrectly. water bucket not seated securely and built-in pump or pump sensing problem can produce the same code, so verify the fault before replacing components.
Possible causes
Check the most likely causes first
- 1
pump hose installed incorrectly
Start here when it matches your symptoms.
- 2
water bucket not seated securely
- 3
built-in pump or pump sensing problem
Diagnostic sequence
Work through these checks in order
Stop when you find the fault. Do not perform a step that requires skills or live testing you are not qualified to do.
- 1
Check 1
Make sure the pump hose is installed correctly.
- 2
Check 2
Remove and securely reseat the water bucket.
- 3
Check 3
Unplug the dehumidifier for 30 seconds and reconnect power.
- 4
Check 4
If E01 returns, consult the model manual or service provider.
Replacement part reference
Dehumidifier Drain Pump
Exact OEM part number
Model number required
Fitment note
The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.
Verify the appliance model before ordering.
Manufacturers can use different parts under the same error code across model families and production revisions.
Where do I find my model number? →FixCodeDB may earn a commission from qualifying purchases made through affiliate links.
Common questions
Quick answers for this fault
What should I check first for E01?
Start with pump hose installed incorrectly. If that checks out, continue through the diagnostic sequence above rather than replacing a part based on the code alone.
Does E01 always mean Dehumidifier Drain Pump is bad?
No. An error code identifies the condition the control detected, not a guaranteed failed part. Confirm the likely causes and wiring first. The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.
When should I stop troubleshooting E01 myself?
Stop if the next step requires live electrical testing, sealed-system work, gas or combustion service, or any procedure outside your training. Disconnect electrical power before removing panels or handling internal components. Do not bypass safety devices or perform live electrical testing unless you are qualified to do so.
Manufacturer reference
Verify against the official support source
FixCodeDB summarizes the fault in plain language. For model-specific instructions, confirm the guidance with the manufacturer and your appliance manual.
GE Dehumidifier Fault Codes — GE Appliances →Was this useful?
Did these checks help with your GE E01 error?
Keep diagnosing
Related GE guides
H2O code indicates insufficient water entered the dishwasher sump during the wash fill cycle.
F3 indicates the main control board senses a stuck or shorted touch key switch on the membrane.
SENSOR ERROR occurs when the humidity/steam sensor fails to send valid voltage signals during Sensor Cook mode.
Bad Line appears when the range or oven detects incorrect electrical wiring at the power connection.
Different problem?
Search another code or symptom
Go back to the main diagnostic search and try the code, symptom, appliance, component, or brand.
Open diagnostic search →