RheemFurnaceCode 11

Rheem Furnace Code 11 - Ignition Failure / No Flame Detected

Code 11 triggers on Rheem and Ruud furnaces when main flame is not established within 4 seconds of gas valve opening.

Quick diagnosis

What this code is telling you

Most likely trigger

Gas supply valve shut off or gas line air lock

Recommended replacement

Hot Surface Igniter (HSI)

Diagnostic path

4 ordered checks

Part fit

Exact model number required

Safety first

Before opening the appliance

Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.

Read the full safety disclaimer

Root cause

Why the control reported this error

The furnace control locks out or reports this fault when the expected ignition, airflow, pressure, flame, or limit sequence is not proven. Check gas supply valve shut off or gas line air lock first, then verify dirty or defective hot surface igniter and faulty gas valve solenoid coil before replacing hot Surface Igniter (HSI).

Symptoms

What you may notice

  • ✓Igniter glows bright orange but gas fails to catch light
  • ✓Furnace retries 3 times then enters 1-hour soft lockout
  • ✓Display shows code 11

Possible causes

Check the most likely causes first

  1. 1

    Gas supply valve shut off or gas line air lock

    Start here when it matches your symptoms.

  2. 2

    Dirty or defective hot surface igniter

  3. 3

    Faulty gas valve solenoid coil

  4. 4

    Sooted flame sensor

Diagnostic sequence

Work through these checks in order

Stop when you find the fault. Do not perform a step that requires skills or live testing you are not qualified to do.

  1. 1

    Check 1

    Disconnect electrical power before opening panels. Confirm shutoff gas valve handle is parallel to pipe line.

  2. 2

    Check 2

    Disconnect electrical power before opening panels. Check igniter for white hot spots or cracks; test resistance (typical 40-90 ohms).

  3. 3

    Check 3

    Clean flame sensor probe with steel wool.

  4. 4

    Check 4

    Replace hot surface igniter.

Replacement part reference

Hot Surface Igniter (HSI)

Exact OEM part number

Model number required

Fitment note

The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.

Verify the appliance model before ordering.

Manufacturers can use different parts under the same error code across model families and production revisions.

Where do I find my model number? →
Search this replacement part on eBay →

FixCodeDB may earn a commission from qualifying purchases made through affiliate links.

Common questions

Quick answers for this fault

What should I check first for 11?

Start with gas supply valve shut off or gas line air lock. If that checks out, continue through the diagnostic sequence above rather than replacing a part based on the code alone.

Does 11 always mean Hot Surface Igniter (HSI) is bad?

No. An error code identifies the condition the control detected, not a guaranteed failed part. Confirm the likely causes and wiring first. The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.

When should I stop troubleshooting 11 myself?

Stop if the next step requires live electrical testing, sealed-system work, gas or combustion service, or any procedure outside your training. Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.

Was this useful?

Did these checks help with your Rheem 11 error?

Keep diagnosing

Related Rheem guides

View Furnace hub →

Different problem?

Search another code or symptom

Go back to the main diagnostic search and try the code, symptom, appliance, component, or brand.

Open diagnostic search →