Quick diagnosis
What this code is telling you
Most likely trigger
Foreign object jamming cross flow fan wheel
Recommended replacement
Indoor Blower Fan Motor
Diagnostic path
4 ordered checks
Part fit
Exact model number required
Safety first
Before opening the appliance
Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.
Read the full safety disclaimerRoot cause
Why the control reported this error
The mini-split control reports this code when a fan, sensor, communication, or refrigerant-system condition is not being confirmed. Start with foreign object jamming cross flow fan wheel, then rule out dust buildup binding fan bearings and defective indoor fan motor before replacing indoor Blower Fan Motor.
Symptoms
What you may notice
- ✓Indoor unit louver opens but air does not blow
- ✓Unit shuts off after 1 minute
- ✓Remote control shows error code A6
Possible causes
Check the most likely causes first
- 1
Foreign object jamming cross flow fan wheel
Start here when it matches your symptoms.
- 2
Dust buildup binding fan bearings
- 3
Defective indoor fan motor
- 4
Faulty indoor unit PCB
Diagnostic sequence
Work through these checks in order
Stop when you find the fault. Do not perform a step that requires skills or live testing you are not qualified to do.
- 1
Check 1
Inspect cross flow fan blower wheel inside indoor head for dust mats or obstructions.
- 2
Check 2
Check fan rotor spin by hand while power is disconnected.
- 3
Check 3
Disconnect electrical power before opening panels. Test motor harness plug connections on indoor board.
- 4
Check 4
Replace indoor fan motor unit.
Replacement part reference
Indoor Blower Fan Motor
Exact OEM part number
Model number required
Fitment note
The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.
Verify the appliance model before ordering.
Manufacturers can use different parts under the same error code across model families and production revisions.
Where do I find my model number? →FixCodeDB may earn a commission from qualifying purchases made through affiliate links.
Common questions
Quick answers for this fault
What should I check first for A6?
Start with foreign object jamming cross flow fan wheel. If that checks out, continue through the diagnostic sequence above rather than replacing a part based on the code alone.
Does A6 always mean Indoor Blower Fan Motor is bad?
No. An error code identifies the condition the control detected, not a guaranteed failed part. Confirm the likely causes and wiring first. The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.
When should I stop troubleshooting A6 myself?
Stop if the next step requires live electrical testing, sealed-system work, gas or combustion service, or any procedure outside your training. Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.
Was this useful?
Did these checks help with your Daikin A6 error?
Keep diagnosing
Related Daikin guides
Different problem?
Search another code or symptom
Go back to the main diagnostic search and try the code, symptom, appliance, component, or brand.
Open diagnostic search →