CarrierFurnaceCode 31

Carrier Furnace Code 31 - High Pressure Switch Did Not Close

Code 31 signals that the furnace draft inducer motor ran, but the pressure switch failed to sense proper negative draft pressure.

Quick diagnosis

What this code is telling you

Most likely trigger

Blocked PVC vent exhaust or fresh air intake pipe

Recommended replacement

Furnace Pressure Switch Assembly

Diagnostic path

4 ordered checks

Part fit

Exact model number required

Safety first

Before opening the appliance

Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.

Read the full safety disclaimer

Root cause

Why the control reported this error

The furnace control locks out or reports this fault when the expected ignition, airflow, pressure, flame, or limit sequence is not proven. Check blocked PVC vent exhaust or fresh air intake pipe first, then verify cracked or disconnected pressure switch silicone tubing and failed inducer blower assembly before replacing furnace Pressure Switch Assembly.

Symptoms

What you may notice

  • ✓Furnace attempts startup but fails to ignite
  • ✓Draft inducer motor hums or spins continuously
  • ✓Status LED flashes 3 short, 1 long

Possible causes

Check the most likely causes first

  1. 1

    Blocked PVC vent exhaust or fresh air intake pipe

    Start here when it matches your symptoms.

  2. 2

    Cracked or disconnected pressure switch silicone tubing

  3. 3

    Failed inducer blower assembly

  4. 4

    Defective pressure switch

Diagnostic sequence

Work through these checks in order

Stop when you find the fault. Do not perform a step that requires skills or live testing you are not qualified to do.

  1. 1

    Check 1

    Check exterior PVC flue termination pipes for bird nests, ice, or debris.

  2. 2

    Check 2

    Clear condensate drain lines and trap of standing water.

  3. 3

    Check 3

    Inspect clear pressure tube for cracks, moisture drops, or loose ports.

  4. 4

    Check 4

    Disconnect electrical power before opening panels. Replace draft inducer pressure switch.

Replacement part reference

Furnace Pressure Switch Assembly

Exact OEM part number

Model number required

Fitment note

The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.

Verify the appliance model before ordering.

Manufacturers can use different parts under the same error code across model families and production revisions.

Where do I find my model number? →
Search this replacement part on eBay →

FixCodeDB may earn a commission from qualifying purchases made through affiliate links.

Common questions

Quick answers for this fault

What should I check first for 31?

Start with blocked pvc vent exhaust or fresh air intake pipe. If that checks out, continue through the diagnostic sequence above rather than replacing a part based on the code alone.

Does 31 always mean Furnace Pressure Switch Assembly is bad?

No. An error code identifies the condition the control detected, not a guaranteed failed part. Confirm the likely causes and wiring first. The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.

When should I stop troubleshooting 31 myself?

Stop if the next step requires live electrical testing, sealed-system work, gas or combustion service, or any procedure outside your training. Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.