BryantFurnaceCode 14

Bryant Furnace Code 14 - Ignition Lockout Fault

Code 14 signals furnace failed to maintain flame control after 4 consecutive ignition retry attempts.

Quick diagnosis

What this code is telling you

Most likely trigger

Soiled or oxidized flame sensor

Recommended replacement

Furnace Flame Sensor Rod

Diagnostic path

4 ordered checks

Part fit

Exact model number required

Safety first

Before opening the appliance

Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.

Read the full safety disclaimer

Root cause

Why the control reported this error

The furnace control locks out or reports this fault when the expected ignition, airflow, pressure, flame, or limit sequence is not proven. Check soiled or oxidized flame sensor first, then verify disconnected ground wire and low gas supply pressure before replacing furnace Flame Sensor Rod.

Symptoms

What you may notice

  • ✓Burners light briefly then go out
  • ✓Igniter glows repeatedly without establishing sustained flame
  • ✓LED blinks 1 short, 4 long flashes

Possible causes

Check the most likely causes first

  1. 1

    Soiled or oxidized flame sensor

    Start here when it matches your symptoms.

  2. 2

    Disconnected ground wire

  3. 3

    Low gas supply pressure

  4. 4

    Defective spark module / igniter

Diagnostic sequence

Work through these checks in order

Stop when you find the fault. Do not perform a step that requires skills or live testing you are not qualified to do.

  1. 1

    Check 1

    Clean flame sensor rod with fine steel wool.

  2. 2

    Check 2

    Check cabinet ground wire connection for tight contact.

  3. 3

    Check 3

    Disconnect electrical power before opening panels. Verify gas valve is turned completely on.

  4. 4

    Check 4

    Replace flame sensor rod.

Replacement part reference

Furnace Flame Sensor Rod

Exact OEM part number

Model number required

Fitment note

The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.

Verify the appliance model before ordering.

Manufacturers can use different parts under the same error code across model families and production revisions.

Where do I find my model number? →
Search this replacement part on eBay →

FixCodeDB may earn a commission from qualifying purchases made through affiliate links.

Common questions

Quick answers for this fault

What should I check first for 14?

Start with soiled or oxidized flame sensor. If that checks out, continue through the diagnostic sequence above rather than replacing a part based on the code alone.

Does 14 always mean Furnace Flame Sensor Rod is bad?

No. An error code identifies the condition the control detected, not a guaranteed failed part. Confirm the likely causes and wiring first. The exact OEM part number varies by model and production revision. Verify the complete model number before ordering.

When should I stop troubleshooting 14 myself?

Stop if the next step requires live electrical testing, sealed-system work, gas or combustion service, or any procedure outside your training. Unplug the appliance before removing panels or testing internal components. Do not bypass safety switches or live-test high-voltage, gas, refrigerant, or combustion components unless you are qualified to do so.

Was this useful?

Did these checks help with your Bryant 14 error?

Keep diagnosing

Related Bryant guides

View Furnace hub →

Different problem?

Search another code or symptom

Go back to the main diagnostic search and try the code, symptom, appliance, component, or brand.

Open diagnostic search →